Home > Hardware > Networking > Terminal Servers >

LES431A Black Box LES400 Device Server


LES431A


 

Direct ship from manufacturer, lead time varies

Your Price: $375.66


Mfg. Part:: LES431A
quantity:

Overview Technical Specifications Why Choose Us to Buy
 
  • UL® Listed for use in Class 1 Division 2 hazardous areas.
  • NEMA TS-2 rated for use in transportation applications.
  • Routes Modbus traffic based on Modbus ID, and remaps conflicting Modbus IDs.
  • Offers Modbus messaging priority control, selectable by source or function code.
  • Features a built-in Web server and easy-to-use management software.
  • It can be easily integrated into most Modbus network configurations.
  • Converts ASCII to RTU as well as ASCII or RTU to Modbus TCP.
  • Features a DB9 port and terminal block for serial connections.
  • Equipped with a 10-/100-Mbps port for TCP connectivity.
  • Boasts high throughput with low latency.
  • Slim IP30 enclosure saves you on DIN rail space.
  • Includes a DIN mounting clip and spring.

Easily integrate an older serial Modbus device into your Ethernet Modbus network. This rugged serial server gives you a simple way to migrate to an Ethernet-based industrial control system - without having to replace the older Modbus equipment you've already invested in.

Translating older and newer protocols, the 1-Port Modbus Hardened Serial Server converts mismatched serial baud rates and settings, enabling the serial Modbus device to become a node on your Ethernet network. Older PLCs can then talk to newer sensors, meters, scales, and other industrial monitoring and automation instruments.

Configuration can be done through a direct serial connection or via the network, so you can improve productivity and cut down on the amount of time required to troubleshoot a serial device on a factory floor or in a remote location. Configure devices, upgrade firmware, and more - all this from the comfort of your office.

A simple-to-install, user-friendly software application enables programming. No time-consuming setup is required. The software also features Modbus messaging priority control and allows management through multiple TCP/IP client sessions. The serial server can be configured for TCP client or server operation.

A built-in traffic monitor provides instant verification of a successfUL® installation, and you can view the serial server's operational status in real-time.

The 1-Port Modbus Hardened Serial Server has a standard DB9 serial port for RS-232 device connections and a removable terminal block for an RS-422 or RS-485 device connection. It also has an autodetecting 10BASE-T/100BASE-TX port for the Ethernet network connection.

Either device on either side can be a Modbus master or slave, customizable to your application. A serial master can be configured to control an IP slave, for instance. Also, a serial slave device can be accessed over a LAN or WAN by up to 16 simultaneous Modbus TCP masters.

Key Features


  • Product Description
    • UL® Listed for use in Class 1 Division 2 hazardous areas.
    • NEMA TS-2 rated for use in transportation applications.
    • Routes Modbus traffic based on Modbus ID, and remaps conflicting Modbus IDs.
    • Offers Modbus messaging priority control, selectable by source or function code.
    • Features a built-in Web server and easy-to-use management software.
    • It can be easily integrated into most Modbus network configurations.
    • Converts ASCII to RTU as well as ASCII or RTU to Modbus TCP.
    • Features a DB9 port and terminal block for serial connections.
    • Equipped with a 10-/100-Mbps port for TCP connectivity.
    • Boasts high throughput with low latency.
    • Slim IP30 enclosure saves you on DIN rail space.
    • Includes a DIN mounting clip and spring.

    Easily integrate an older serial Modbus device into your Ethernet Modbus network. This rugged serial server gives you a simple way to migrate to an Ethernet-based industrial control system - without having to replace the older Modbus equipment you've already invested in.

    Translating older and newer protocols, the 1-Port Modbus Hardened Serial Server converts mismatched serial baud rates and settings, enabling the serial Modbus device to become a node on your Ethernet network. Older PLCs can then talk to newer sensors, meters, scales, and other industrial monitoring and automation instruments.

    Configuration can be done through a direct serial connection or via the network, so you can improve productivity and cut down on the amount of time required to troubleshoot a serial device on a factory floor or in a remote location. Configure devices, upgrade firmware, and more - all this from the comfort of your office.

    A simple-to-install, user-friendly software application enables programming. No time-consuming setup is required. The software also features Modbus messaging priority control and allows management through multiple TCP/IP client sessions. The serial server can be configured for TCP client or server operation.

    A built-in traffic monitor provides instant verification of a successfUL® installation, and you can view the serial server's operational status in real-time.

    The 1-Port Modbus Hardened Serial Server has a standard DB9 serial port for RS-232 device connections and a removable terminal block for an RS-422 or RS-485 device connection. It also has an autodetecting 10BASE-T/100BASE-TX port for the Ethernet network connection.

    Either device on either side can be a Modbus master or slave, customizable to your application. A serial master can be configured to control an IP slave, for instance. Also, a serial slave device can be accessed over a LAN or WAN by up to 16 simultaneous Modbus TCP masters.


  • Media Type Supported: Twisted Pair
  • Ethernet Technology: Fast Ethernet
  • Network Standard: 10/100Base-TX
  • Network (RJ-45): Yes
  • Serial Port: Yes
  • Number of Network (RJ-45) Ports: 1
  • Number of Serial Ports: 1
  • Form Factor: DIN Rail Mountable
  • Height: 1.2"
  • Width: 3.2"
  • Depth: 4.7"
  • Weight (Approximate): 4.80 oz
  • Environmentally Friendly: Yes
  • Country of Origin: United States
  • TAA Compliant: Yes
  • Limited Warranty: 5 Year

Share your knowledge of this product with other customers... Write a review

Browse for more products in the same category as this item:

Hardware > Networking > Terminal Servers
Hardware > Networking
Industries > Government
Black Box